Product BrochureYoutube VideoThe QuickTOCcondensate TOC Analyzer

QuickTOCcondensate Monitors TOC in Boiler Condensate

Fast, Accurate, Low-maintenance Monitoring of TOC

 

  • Product Overview

  • Technical Specifications

The QuickTOCcondensate is a high temperature combustion TOC analyzer that has been optimized to the needs of boiler condensate monitoring. For some analyzers, calibration and validation of the TOC analysis can be difficult in lower measuring ranges (0-2.000 µg/L). Using the newly developed "gas calibration", a patent-pending method from LAR, this procedure has been significantly simplified. The QuickTOCcondensate works without the usual risk of contamination and has no need for a calibration solution. Even at the lowest measuring ranges the calibration can easily be performed and verfified with the calibration gas.

FEATURES & BENEFITS:

• Catalyst-Free Technique
• Highest Combustion Temperature (1200°C)
• Easiest Calibration and Validation
• Menu-Guided Operation
• Closed System Design Resists Sample Contamination
• Rapid Response-Time of 3 - 5 Minutes
• High Reproducibility
• Low Cost of Operation
• Infrared Detection
• Low Maintenance
• TNb Detection Available
• Dual Channel Measurement Option

QuickTOCultra Video on YouTubeYouTube Video: http://tinyurl.com/qtultra
Webinar: Comparing BOD, COD & TOC: http://tinyurl.com/bod5webinar



Technical Data

Measurement and Sample Preparation

Type of measurement:
thermal combustion at 1200°C
Measuring range: 0 - 2,000 ppb (µg/L), 0.1 - 10/20 ppm (mg/L)
Response time:
3- 5 minutes (application dependent)
Reproducibility:
2% or ± 10 ppb
Accuracy:
± 2%


Operation and Data Output

Display is back-lit Graphic-LCD-screen, high resolution, back-lit
Autostart-function
Menu-guided operation including maintenance checklists and support for Industry-standard data interface

Connections


Sample water, in stainless steel tube OD 6mm (Swagelok)
Sample water, drain: PVC tube OD 8mm
Electrical power: ~115 / 230V, 50 / 60 Hz
Analog output: 0/4 - 20 mA
Serial interface: RS 232 for remote control, Malfunction alarm, life-zero
Status output: 4 relay contacts
Remote control: via TCP/ IP protocol (internet)

Dimensions and Weight

Cabinet: steel IP54 (NEMA 13)
Optional: NEMA 4X (ClassI Div 2), IP 65, ATEX zone 1 and zone 2
Dimensions: 1,060 x 600 x 520mm (H x W x D) ~(41.7 x 23.6 x 20.5 inches)
Weight: approx. 115 kg (254 lb)

 

 

 